Ability to control user access to controller parameters. Parameter access can be customized by using the Tridium Niagara Workbench tool. Programmable for: Home screen options, tenant access, contractor access, access to controller parameters, setpoint, override, fan, and other parameters. Supplied with eight pre-programmed configurations (e.g. VAV with balancing) in the wall module configuration tool. Ability to access and adjust most parameters in the programmable controller (except Scheduling). Ability to balance the VAV system from the wall module. Home screen can display one to three of any of the following parameters: Temperature Setpoint, Room Temperature, Room Humidity, Outdoor Humidity, Outdoor Temperature, and Time, or one of virtually any parameter in the controller. Network bus jack. Simple 2-wire terminal connection to the programmable controller and an optional 2-wire terminal connection for the network. All connections are polarity insensitive. Retention of user configuration, including setpoints after a power outage.Zio LCD/Two-wire Sylk Wall ModuleNetwork Communications | Two-wire Sylk and Network Jack |
---|
Overview | The TR70 and TR70-H are 2-wire, non-polarity sensitive, Sylk™ bus communicating wall modules for use with Spyder™ programmable controllers which are compatible with the Sylk bus. All models have a space-temperature sensor, network bus jack, and an LCD with three soft keys and two Up/Down adjustment keys. Like the TR71, but includes access to controller schedule and has more memory for additional parameters |
---|
Setpoint Temperature Range (F) | Default range is 55 F to 85 F; configurable for other ranges |
---|
Setpoint Temperature Range (C) | Default range is 10 C to 35 C; configurable for other ranges |
---|
Switch Positions (Fan) | Configurable |
---|
Application | Wall Module Temperature Sensor |
---|
Approvals, Federal Communications Commission | FCC Part 15 |
---|
Comments | Configurable with Niagara Workbench |
---|
Accuracy (C) | ±0.2 C at 25 C |
---|
Accuracy (F) | ±0.36 F at 77 F |
---|
Operating Humidity Range (% RH) | 5 to 95% RH, non-condensing |
---|
Operating Temperature Range (F) | 30 F to 110 F |
---|
Used With | Spyder Sylk Enhanced |
---|
Operating Temperature Range (C) | -1 C to 43 C |
---|
Dimensions (mm) | 84 mm wide x 117 mm high x 24 mm deep |
---|
Approvals, Underwriters Laboratories Inc | UL94-HB plastic enclosure |
---|
Dimensions (in.) | 3 5/16 in. wide x 4 5/8 in. high x 15/16 in. deep |
---|
Shipping and Storage Temperature Range (C) | -40 C to 65.5 C |
---|
Shipping and Storage Temperature Range (F) | -40 F to +150 F |
---|
Parameter Memory (Bites) | 2K |
---|
Product Family
All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.
UPS Hoilday Delivery Schedule
For more infomation about Returns visit Returns
For more informatrion about Warranty visit Warranty page.
You can also find answers to some common questions on our FAQ page
Reviews
Not reviewed yet, be the first to write one!
Add Review
|