• Totally enclosed Micro Switch™ sN/Ap-acting switches operate on temperature rise to setpoint.
• Visible control point scale and exterN/Al adjustment screw permit easy setting.
• Horizontal or vertical insertion of the sensing element.
• Direct or well immersion of the sensing element.
• Models available for strap-on mounting.
• Remote bulb model may be used to sense air temperature in ducts and in outside air sensing Applications.
• TRADELINE models include heat-conductive compound.
• Select models have wells.
• UL limit rated device.AQUASTAT M/R 130-270F OP/RISEApplication | High limit, manual reset aquastat controller. Operates at 130 F to 270 F These boiler-mounted, immersion type controllers
operate in response to temperature changes in hydronic
heating systems.
L4006A breaks the circuit on a temperature rise to the
control setting. It is used for high limit or low limit
control. When used as a controller or as a low limit, a
separate high limit must be used.
L4006B makes the circuit on a temperature rise. It is
used as a circulator controller, delaying circulator
operation when boiler water temperature is below the
control setting.
L4006E,H includes a trip-free manual reset switch.
These models are designed to break the control circuit
whenever the temperature of the controlled medium
reaches the high limit setting. A reset button on the front
of the case must be pressed to re-establish the control
circuit. L4006H also includes bracket and clamp for
surface mounting on pipe or tank.
A plastic bag of heat-conductive compound is included
with the L4006A,B,E Aquastat® Controllers for use when
the sensing bulb is inserted into a well designed for a
large bulb than the one used on the L4006A,B,E. A
124904 Well Adapter, for use on old wells that do not fit
the L4006A,B,E immersion well clamp, can be ordered;
see form 68-0040, Wells and Fittings for Temperature
Controllers. A setting stop is included to prevent setting
above a desired temperature on limit.
If a well adapter or other accessories are needed, refer to
form 68-0040, Wells and Fittings for Temperature
Controllers, for part numbers and ordering information. |
---|
Application | High Limit; Manual Reset |
---|
Differential Temperature (F) | Manual Reset |
---|
Differential Temperature (C) | Manual Reset |
---|
Dimensions (mm) | Case--143 mm high x 51 mm wide x 54 mm deep |
---|
Operating Temperature Range (F) | 130 F to 270 F |
---|
Operating Temperature Range (C) | 54 C to 132 C |
---|
Electrical Ratings | Millivolt--0.25 A @ 0.25 to 12 Vdc; At Full Load-- 8A @ 120 Vac: 1.3A @ 240 Vac; At Locked Rotor-- 48A @ 120 Vac: 30.6A @ 240 Vac |
---|
Includes | Stop factory-set at 250 F (121 C) |
---|
Capillary Length (in.) | 1 1/2 in. |
---|
Capillary Length (mm) | 38 mm |
---|
Product Family
All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.
UPS Hoilday Delivery Schedule
For more infomation about Returns visit Returns
For more informatrion about Warranty visit Warranty page.
You can also find answers to some common questions on our FAQ page
Reviews
Not reviewed yet, be the first to write one!