GLOBE VALVEActuator Type | Electronic fail-safe |
---|
Control Type | Floating/3-point |
---|
Electrical Connection | cable |
---|
Degree of Protection | NEMA�2, UL�Enclosure�Type�2 |
---|
Force | 450 lbf [2000 N force] |
---|
Application | The FGVL retrofit kit is designed to easily attach AVK, EV and RV series actuators to select Flanged globe valves requiring larger stem travels and higher forces. Its casted base and lower locking clamp allow the FGVL to be mounted on 2-1/2? to 6? two-way or three-way valves in both normally open and normally closed configurations |
---|
Service | chilled or hot water and steam |
---|
Media Temperature Range (Water) | 20�F to 250�F [-7�C to 120�C] |
---|
Servicing | maintenance free |
---|
Power Supply | 24 VAC � 20%, 50/60 Hz |
---|
Power Consumption Running | 5 W |
---|
Power Consumption Holding | 2 W |
---|
Transformer Sizing | 9.5 VA (class 2 power source) |
---|
Electrical Connection | 3 ft, 18 GA plenum rated cable with 1/2? conduit connector protected NEMA 2 (IP54) |
---|
Overload Protection | electronic throughout full stroke |
---|
Input Impedance | 100 k ? (0.1 mA), 500 ?, 1000 ? (on/off) |
---|
Direction of Rotation (Motor) | reversible with switch |
---|
Manual Override | 5 mm hex crank (3/16? Allen), supplied |
---|
Running Time (Motor) | 90 sec, constant independent of load |
---|
Ambient Temperature Range | -22�F to +122�F [-30�C to +50�C] |
---|
Storage Temperature Range | -40�F to +176�F [-40�C TO +80�C] |
---|
Housing | NEMA 2, IP54, UL enclosure type 2 |
---|
Agency Listings | cULus acc. to UL60730-1A/-2-14, CAN/CSA
E60730-1:02, CE acc. to 2004/108/EC and
2006/95/EC |
---|
Noise Level (Motor) | <60 dB (A) |
---|
Operating Range Y | on/off, floating point |
---|
Direction of Rotation (Fail-Safe | reversible with switch |
---|
Position Indication | stroke indicator on bracket |
---|
Running Time (Fail-Safe) | 35 sec |
---|
Noise Level (Fail-Safe) | <60 dB (A) |
---|
Feedback Output U | No Feedback |
---|
Housing Material | Aluminum die cast and plastic casing |
---|
Electrical protection | actuators are double insulated |
---|
Media Temperature Range (Steam) | 32�F to 338�F [0�C to 170�C] |
---|
Humidity | 5 to 95% RH non-condensing |
---|
Stroke | 1.25? [32 mm] AVK, 2? [50 mm] EV/RV |
---|
Linear Force | 450 lbf [2000 N force] |
---|
Bridge Time | 2 sec delay before fail-safe activates |
---|
Applicable Valve Size | 2-1/2? [64], 3? [80], 4? [101], 5? [127], 6? [152] |
---|
Frame, plate, base | aluminum, steel (fits competitor bonnets up to 2.3? dia.) |
---|
Coupling | GF Nylon supplied |
---|
Stem Adaptor | steel/Aluminum |
---|
Pre-charging | Time 5 to 20 seconds |
---|
Default/Configuration | The default set up for a FGVL linkage will be factory installed along with an AVK or EV, RV series actuator. Included in the kit will be all the necessary hardware to facilitate mounting to the valve. |
---|
Product Family
All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.
UPS Hoilday Delivery Schedule
For more infomation about Returns visit Returns
For more informatrion about Warranty visit Warranty page.
You can also find answers to some common questions on our FAQ page
Reviews
Not reviewed yet, be the first to write one!
Add Review
|