TECHNICAL SPECIFICATIONS
Display: LCD with a maximum reading of 4000.
Data Hold: Operating on all ranges
Range(RNG): Operating on all autoranges
Overrange: "OL" mark indication.
Auto power off: Approx. 10 minutes.
Measurement rate: 2 times per second, nominal.
Operating environment: 32 to 122°F (0 to 50°C) at <70% R.H.
Storage temperature: -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed.
Accuracy: Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°) , <75% relative humidity.
Temperature Coefficient: 0.1 × (specified accuracy) per °F/°C; 32 to 66°F (0 to 19°C); 82 to 122°F (28 to 50°C).
Altitude: 6561.7 Feet (2000 meters).
Jaw opening capability: 38mm conductor.
Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22.
Battery life: 100 hours carbon zinc, 200 hours typical with alkaline.
Accessories: One pair test leads, one pair of small alligator clips, ktype thermocouple, 9V battery (installed), and operating instructions.
Safety: Designed to meet IEC/EN61010-1 and IEC/EN61010- 2-032, CATIII 600V, class II and pollution degree 2, indoor use comply with CE. C-Tick.

DC volts
Ranges: 400mV, 4000mV, 40V, 400V, 600V
Resolution: 0.1mV
Accuracy: ±(0.5% rdg + 2 dgt)
Input impedance: 3MO on V inputs, 10MO on mV input
Overload protection: 600VDC or AC rms
Transient protection: 6kV for 10µ sec

AC volts(50Hz - 500Hz)
Ranges: 4V, 40V, 400V, 600V
Resolution: 1mV
Accuracy: ±(2.0% rdg + 8 dgts) 50 ~ 500Hz
Input impedance: 3MO
Overload protection: 600V DC or AC rms
Transient protection: 6kV for 10µ sec

AC current(50Hz - 60Hz)
Ranges: 40A, 300A
Resolution: 0.01A
DC Accuracy:
±(3.0% rdg + 10 dgts) 0 ~ 300A / 50 ~ 60Hz
Overload protection: 300AAC

DC current
Ranges: 400µA
Resolution: 0.1µA
Accuracy: ±(1.0% rdg + 2 dgt)
Voltage burden: 1V
Overload protection: 500V DC or AC rms

Resistance
Ranges: 400O, 4kO, 40kO, 400kO, 4MO, 40MO
Resolution: 0.1O
Accuracy:
±(1.2% rdg + 4 dgts) on 400O to
400kO ranges
±(1.5% rdg + 4 dgts) on 4MO range
±(3.0% rdg + 5 dgts) on 40MO range
Open circuit volts: -0.45VDC typical,
(-1.2VDC on 400O range)
Overload protection: 500VDC or AC rms

Temperature
Range: -30 to 1000°F (-35 to 600°C)
Resolution: 0.1°
Accuracy: ±1°F (32 to 120°F)
±1% + 1.5°F (-4 to 750°F)
±2% + 4°F (-30 to -4°F, 750 to1000°F)
±1°C (0 to 120°C),
±1% + 1°C (0 to 400°C)
±2% +3°C (-35 to 0°C, 400 to 600°C)
Sensor type: K-type thermocouple
Overload protection: 60 VDC or 30 VAC rms

Continuity
Range: 400O
Resolution: 1O
Audible indication: Less than 25O
Response time: 500ms
Overload Protection: 500VDC or AC rms
Green LED will be on continuously.

Capacitance
Range: 4µF, 40µF, 400µF, 4mF
1mF = 1000µF
i.e: 1.425mF = 1425µF
Resolution: 1nF
Accuracy: ±(3% rdg + 10 dgts) on 4µF range
±(3% rdg + 5 dgts) on 40µF to 400µF ranges
±(5% rdg + 20 dgts) on 4mF range
Input protection: 500VDC or AC rms

Hi-V(voltage) warning
>30VAC/DC meter beeps, red LED blinks.
Non-contact voltage
Senses voltage 24V to 600V AC (50Hz to 60Hz) beeper chirps and big bright red LED comes on, works when meter dial is on any range.


Product Family

Model NumberDecriptionManufacturerPriceAvail. Qty 
SC76 HVAC/R Clamp Meter with Temperature and Capacitance Fieldpiece Instruments Call for Pricing 0    View More Info

Coming Soon

All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.

UPS Hoilday Delivery Schedule

For more infomation about Returns visit Returns

For more informatrion about Warranty visit Warranty page.

You can also find answers to some common questions on our FAQ page

Reviews

Not reviewed yet, be the first to write one!

Add Review

Customers who bought this item also bought: