TECHNICAL SPECIFICATIONS
Display: 3¾ digit liquid crystal display (LCD) with a maximum reading of 3999.
Range: Manual ranging mode (SC44 & SC45), hold button for 2 seconds to return to autoranging mode.
Overrange: "OL" or “-OL” mark indication.
Auto power off: 10 minutes.
Operating environment: 32 to 122°F (0 to 50°C), at <70% R.H.
Storage temperature: -4 to 140°F (-20 to 60°C), @ <80% R.H. with batteries removed.
Accuracy: Specifications good in ambient conditions of 74°F ±8°F (23°C ±4°C), <75% relative humidity.
Temperature coefficient: 0.1×(specified accuracy) per °F/°C; 32 to 66°F (0 to 19°C); 82 to 122°F(28 to 50°C).
Altitude: 6561.7 feet (2000m).
Power: Two AAA 1.5V batteries.
Battery life: 400 hours typical with alkaline.
Accessories: One pair test leads, (2) 1.5V AAA batteries (installed), carrying case and operating instructions.
Safety: Designed to meet IEC61010-1 (EN61010-1) and IEC61010-2-032 (EN61010-2-032), clamp is CATIII 300V, class II, voltage Cat.III 600V, and pollution degree 2 indoor use comply with CE, C-tick certified, UL listed..

DC volts
Ranges: 400mV, 4V, 40V, 400V, 600V
Resolution: 0.1mV
Accuracy: ±(0.5% rdg + 2 dgt)
Input impedance:
400mV > 100MO, 4V = 10MO, 40V~600V = 9.1MO
Transient protection: 6kV for 10µ sec

AC volts (50Hz - 500Hz)
Ranges: 4V, 40V, 400V, 600V
Resolution: 1mV
Accuracy: ±(1.2% rdg + 5 dgts), ±(1.5% rdg + 5 dgts) on 600V range
Input impedance: 4V = 10MO, 40V~600V = 9.1MO

Resistance
Ranges: 400O, 4kO, 40kO, 400kO, 4MO, 40MO
Resolution: 0.1O
Accuracy:
±(1.0% rdg + 4 dgts) on 400O to 400kO ranges
±(1.5% rdg + 4 dgts) on 4MO range
±(3.0% rdg + 5 dgts) on 40MO range
Open circuit volts: -0.45VDC typical, (-1.2VDC on 400O range)

AC Current (50Hz - 60Hz)
Ranges: 40A, 400A,
Resolution: 0.01A
Accuracy: ±(2.0% rdg + 6 dgts)

Continuity
Audible indication: Less than 25O
Response time: 500ms

Diode Test
Test current: 1.2mA (approximate)
Accuracy: ±(3.0% rdg + 3 dgts)
Resolution: 10mV
Audible indication: Less than 0.25V
Open circuit volts: 3.0VDC typical

Overload Protection
VAC/DC - 600VDC or AC RMS
AAC - 400AAC
Resistance - 500VDC or AC RMS
Continuity - 500VDC or AC RMS
Diode - 500VDC or AC RMS


Product Family

Model NumberDecriptionManufacturerPriceAvail. Qty 
SC44 Mini Clamp Meter for HVAC/R Fieldpiece Instruments Call for Pricing 0    View More Info

Coming Soon

All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.

UPS Hoilday Delivery Schedule

For more infomation about Returns visit Returns

For more informatrion about Warranty visit Warranty page.

You can also find answers to some common questions on our FAQ page

Reviews

Not reviewed yet, be the first to write one!

Add Review