TECHNICAL SPECIFICATIONS
Display: 3¾ digit liquid crystal display (LCD) with a maximum reading of 3999.
Analog bar graph: 41 segments with measurements 20 times per second.
Range (RNG): Manual ranging mode (Press for two seconds to switch between auto range and manual range)
Overrange: "OL" mark indication.
Auto power off: 30 minutes.
Operating environment: 32 to 122°F (0 to 50°C) at <70% R.H.
Storage temperature: -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed.
Accuracy: Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°C), <75% relative humidity.
Temperature coefficient: 0.1×(specified accuracy) per °F/°C. (32 to 64°F (0 to 18°C), 82 to 122°F(28 to 50°C)).
Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22.
Battery life: 300 hours typical with alkaline.
Safety: UL,CE,Cat III600V,UL61010-1,IEC/EN61010-1.

Temperature
Range: -30 to 1000°F (-34 to 538°C)
Resolution: 0.1°F/°C
Accuracy: ±1°F, 32 to 120°F (0 to 49°C),
±1% + 1.5°F, -4 to 750°F (-20 to 399°C),
±2% + 4°F, -30 to -4°F (-34 to -20°C),
±2% + 4°F, 750 to 1000°F (399 to 538°C)
Sensor type: K-type thermocouple
Overload protection: 60 VDC or 30 VAC rms


Continuity
Audible indication: Less than 40O
Response time: 500ms
Green LED will be on continuously.
Overload protection: 500VDC or AC rms

DC volts
Ranges: 400mV, 4000mV, 40V, 400V, 600V
Resolution: 0.1mV
Accuracy: ±(0.5% rdg + 2 dgt)
Input impedance: 3MO on V inputs, 10MO on mV input
Overload protection: 600VDC or AC rms
Transient protection: 6kV for 10µ sec

AC volts (50Hz - 500Hz)
Ranges: 400mV, 4V, 40V, 400V, 600V
Conversion: Average
Resolution: 0.1mV
Accuracy:
±(1.2% rdg + 5 dgts) 50Hz ~ 60Hz on 400mV range
±(1.5% rdg + 5 dgts)
±(2% rdg + 5 dgts) on 600V range
Input impedance: 3MO
Overload protection: 600V DC or AC rms
Transient protection: 6kV for 10µ sec

DC current
Ranges: 400µA, 4000µA
Resolution: 0.1µA
Accuracy: ±(1.0% rdg + 2 dgt)
Voltage burden: 1V, (8V on 4000µA range)
Overload protection: 500V DC or AC rms

Resistance
Ranges: 400O, 4kO, 40kO, 400kO, 4MO, 40MO
Resolution: 0.1O
Accuracy:
±(1.0% rdg + 4 dgts) on 400O to 400kO ranges
±(1.5% rdg + 4 dgts) on 4MO range
±(3.0% rdg + 5 dgts) on 40MO range
Open circuit volts: -0.45VDC typical, (-1.2VDC on 400O range)
Overload protection: 500VDC or AC rms

Capacitance
Range: 400µF
Resolution: 0.1µF
Accuracy: ±(3% rdg + 5 dgts)
Overload protection: 500V DC or AC rms

Frequency
Ranges: 4k, 40k, 400k, 4M, 40MHz
Resolution: 1Hz
Accuracy: ±(0.1% rdg + 3 dgts)
Sensitivity: 10Hz ~ 4MHz: > 1Vrms, 4MHz ~ 40MHz: > 2Vrms, <5Vrms
Minimum pulse width: > 25ns
Duty cycle limits: > 30% and < 70%
Overload protection: 500VDC or AC rms


Product Family

Model NumberDecriptionManufacturerPriceAvail. Qty 
HS35 STICK METER KIT W/CASE,BARGRAPH Fieldpiece Instruments Call for Pricing 0    View More Info

Coming Soon

All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.

UPS Hoilday Delivery Schedule

For more infomation about Returns visit Returns

For more informatrion about Warranty visit Warranty page.

You can also find answers to some common questions on our FAQ page

Reviews

Not reviewed yet, be the first to write one!

Add Review