• Main burner ignition using a 120V hot surface igniter.
• Flame rectification circuit to monitor flame presence.
• Monitoring of system pressure switch, high temperature limit, and rollout functions.
• Appliance operation/safety requirements controlled via microprocessor.
• Control of a standard induction-type circulating fan motor (based on appliance requirements), in response to a conventional low voltage or EnviraCOM™ thermostat.
• LED system status, performance and diagnostic indication.
• Wire harnesses provided for simple replacement of most IFCs and integration with most heating and cooling appliances.
• Twinning capability
• EnviraCOM™ communication capability to enable local and/or remote system status, diagnostics, troubleshooting, and HVAC system control.Honeywell hot surface integrated furnace controlOverview | The S9200U1000 can be used with conventional thermostats as well as the EnviraCOM™ enabled VisionPRO IAQ and FocusPRO. The S9200U1000 Universal Integrated Furnace Control is intended for residential natural or liquid propane fueled furnaces only. The S920 |
---|
Line Voltage | 120Vac (97-132 Vac) |
---|
Low Voltage | 24V (18-30Vac) |
---|
Operating Temperature (F) | -40 F to +175 F |
---|
Operating Temperature (C) | -40 C to +79 C |
---|
Operating Humidity Range (% RH) | 0% to 95% non-condensing |
---|
Igniter Current | 5 A resistive @ 120VAC |
---|
Thermostat Anticipator Setting | (Stage 1 only) 100mA |
---|
HSI Warmup Time | 17/27 or 30/30 seconds |
---|
Trial For Ignition | 4, 6, or 8 seconds |
---|
Ignition Trials | Three, two tries if flame is not sensed |
---|
Flame Failure Response Time | 2 Seconds max @ 1µA |
---|
Heat On Fan Delay | 30 or 60 seconds |
---|
Heat Off Fan Delay | 60, 90, 120, or 180 Seconds |
---|
Cool Fan On Delay | 5 seconds |
---|
Cool Fan Off Delay | 0 or 60 seconds |
---|
Gas Control Used With | Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended. |
---|
Cooling Contactor Used With | Any 24Vac contactor rated at 1.0A or less |
---|
Induced Draft Blower Load | 2.2FLA / 25LRA max @120Vac |
---|
Ciculator Load | 14.5FLA / 25LRA max @120Vac |
---|
Type of Fan Used With | Standard Induction-Type Circulating Fan |
---|
Product Family
All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.
UPS Hoilday Delivery Schedule
For more infomation about Returns visit Returns
For more informatrion about Warranty visit Warranty page.
You can also find answers to some common questions on our FAQ page
Reviews
Not reviewed yet, be the first to write one!
Add Review
|