3-Way 3/4" Characterized Control Valve W/ 24.0Cv and a Brass Trim BodyActuator Type | Spring return |
---|
Close Off Pressure | 200�psi |
---|
End Fitting | Internal thread |
---|
Control Type | Open-close only |
---|
Controllable Flow Range | 75� |
---|
Electrical Connection | cable |
---|
Flow Pattern | Mixing/Diverting |
---|
Application | The 6-way characterized control valve is ideal for chilled beams, radiant ceilings, and Fan Coil Units offering reduced wiring by using a single actuator instead of two. It eliminates the need for a change over valve and enables the use of a single coil for heating and cooling. |
---|
Service | chilled, hot water, up to 60% glycol |
---|
Flow Characteristic | A-port Equal percentage; B-port modified linear for constant flow |
---|
Controllable Flow Range | 75� |
---|
End Fitting | NPT female ends |
---|
Body | forged brass, nickel plated |
---|
Stem Packing | EPDM (lubricated) |
---|
Seat O-ring | EPDM (lubricated) |
---|
Characterized Disc | TEFZEL? |
---|
Body Pressure Rating [psi] | 600 |
---|
Media Temperature Range (Water) | 0�F to 250�F [-18�C to 120�C] |
---|
Max Differential Pressure (Water) | 50 psi (345 kPa) |
---|
Close-Off Pressure | 200 psi |
---|
Leakage | 0% for A to AB, <2.0% for B to AB |
---|
Servicing | maintenance free |
---|
Power Supply | 120 VAC � 10%, 50/60 Hz |
---|
Power Consumption Running | 5.5 W |
---|
Power Consumption Holding | 3.5 W |
---|
Electrical Connection | 3ft [1m], 18 GA appliance cable with 1/2? conduit connector |
---|
Overload Protection | electronic throughout 0� to 95� rotation |
---|
Direction of Rotation (Motor) | reversible with built-in switch |
---|
Running Time (Motor) | <40 to 75 sec |
---|
Ambient Temperature Range | -22�F to 122�F [-30�C to 50�C] |
---|
Storage Temperature Range | -40�F to 176�F [-40�C to 80�C] |
---|
Agency Listings | cULus acc. To UL 873 and CAN/CSA C22.2 No. 24-93 |
---|
Noise Level (Motor) | <50 dB (A) |
---|
Direction of Rotation (Fail-Safe | reversible with CW/CCW mounting |
---|
Position Indication | visual indicator, 0� to 95� (0� is full spring return position) |
---|
Running Time (Fail-Safe) | <25 sec @ -4�F to 122�F [-20�C to 50�C], < 60 sec @ -22�F [-30�C] |
---|
Noise Level (Fail-Safe) | <62 dB (A) |
---|
Product Family
All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.
UPS Hoilday Delivery Schedule
For more infomation about Returns visit Returns
For more informatrion about Warranty visit Warranty page.
You can also find answers to some common questions on our FAQ page
Reviews
Not reviewed yet, be the first to write one!
Add Review
|