• Use in intermittent ignition applications.
• Capable of zone control with zone valves.
• Circulator zone control with ZC and ZR terminals on R8182D,E,H,J. 8*Flame failure during the running cycle results in a 45 second attempt to restart.
• If unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted.
• R8182D,E,F mount directly on burner; R8182H,J mount on 4 x 4 in. junction box and include 5 ft (1.5 m) armored capillary with remote sensor.
• C554A Cadmium Sulfide Flame Detector and a 24 Vac thermostat required.1-1/2 in. Insulation Depth, Combination Protectorerelay and Hydronic Heating ControllerOperating Range, Low Limit (F) | 110 F to 220 F |
---|
Maximum Power Consumption | 9 W |
---|
Overview | Immersion type Aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating systems. |
---|
Operating Range, Low Limit (C) | 43 C to 104 C |
---|
Operating Range, High Limit (F) | 130 F to 240 F |
---|
Maximum Safe Operating Pressure (psi) | 200 psi on immersion well; 100 psi direct immersion. |
---|
Operating Range, High Limit (C) | 54 C to 116 C |
---|
Maximum Safe Operating Pressure (kPa) | 1378 kPa on immersion well; 90 kPa direct immersion. |
---|
Electrical Rating (ignition) | 360 VA |
---|
Electrical Ratings (burner AFL) | 4.4 A @ 120 Vac |
---|
Electrical Ratings (burner ALR) | 26.4 A @ 120 Vac |
---|
Operating Temperature Range (F) | High Limit-- 130 F to 240 F; Low Limit-- 110 F to 220 F |
---|
Operating Temperature Range (C) | High Limit-- 54 C to 116 C; Low Limit-- 43 C to 104 C |
---|
Dimensions (in.) | 7 1/8 in. high x 5 1/4 in. wide x 3 7/16 in. deep. |
---|
Dimensions (mm) | 181 mm high x 133 mm wide x 87 mm deep. |
---|
Insulation Depth (in.) | 1 1/2 in. |
---|
Insulation Depth (mm) | 38 mm |
---|
Operating Humidity Range (% RH) | 0 to 95% RH, non-condensing |
---|
Differential Temperature (F) | High limit: 10 F fixed; Low limit/circulator: 10 F to 25 F adj. |
---|
Maximum Ambient Temperature (F) | 250 F at element |
---|
Maximum Ambient Temperature (C) | 121 C at element |
---|
Approvals, Underwriters Laboratories Inc | UL Listed: File No. listed: MP268, Vol. 3,4 (R8182D,E,F), Vol. 37 (R8182H,J), Sec. 1. |
---|
Approvals, Canadian Standards Association | Certified: File No. LR95329-1 |
---|
Includes | Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay. Heat-conductive compound and vertical case. |
---|
Timing, Safety Switch | 45 sec |
---|
Product Family
All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.
UPS Hoilday Delivery Schedule
For more infomation about Returns visit Returns
For more informatrion about Warranty visit Warranty page.
You can also find answers to some common questions on our FAQ page
Reviews
Not reviewed yet, be the first to write one!
Add Review
|