• These controls communicate directly with an electronic fan timer (ST9160 Electronic Fan Timer for single stage applications; ST9162 Electronic Fan Timer for two-stage applications) in typical forced warm air furnace applications.
• They also interface with the 208907 Terminal Board, providing compatibility with power stealing thermostats. Or, they directly interface with the appropriate power supplies and a system thermostat for additional appliance applications.
• When controlled directly by a thermostat, these controls do not provide a postpurge function, because power to the control is removed when the thermostat call for heat ends.
• The SV9541 Systems are suitable for a wide range of fan-assisted combustion gas-fired appliances including furnaces, rooftop furnaces, boilers, unit heaters, infrared heaters, water heaters and commercial cooking appliances.SUPER TRADELINE. 1/2 NPT INLET X 1/2Approvals, Canadian Standards Association | CSA-International, Design Certified |
---|
Control Voltage (Thermostat or other call for heat) | 24 Vac, 60 Hz. |
---|
Overview | The TRADELINE® SV9541 SmartValve® System Controls combine gas flow control and electronic intermittent pilot sequencing functions into a single unit. The Q3450 or Q3480 Pilot hardware supplies the low voltage igniter, flame sensor and pilot burner. These |
---|
Pressure Tapping | 1/8 in. - NPT |
---|
Includes | LP Conversion Kit |
---|
Tradeline Value | Super Tradeline |
---|
Ignition System Type | Intermittent Hot Surface Pilot Ignition |
---|
Mounting | 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically. |
---|
Dimensions (in.) | 3.2 in. wide x 4.9 in. high x 4.1 in.long |
---|
Ignition Sequence | Intermittent Pilot |
---|
Dimensions (mm) | 81 mm wide x124 mm high x 104 mm long. |
---|
Ignition Trials To Lockout | continuous retry |
---|
Body Pattern | Straight-through |
---|
Opening Characteristics (standard, step) | Standard Opening 2-stage |
---|
Ignition Trial Time (sec) | 90 sec |
---|
Flame Failure Response Time (sec) | 1.6 sec @ 3 µA |
---|
Ambient Temperature Range (F) | -40 F to +175 F |
---|
Ambient Temperature Range (C) | -40 C to +79 C |
---|
Pressure Regulator Setting (psi) | 1.7 in. wc low; 3.2 in. wc high |
---|
Pressure Regulator Setting (kPa) | 0.42 kPa low; 0.80 kPa high |
---|
Pressure Ratings (psi) | 1/2 psi |
---|
Pressure Ratings (kPa) | 3.5 kPa |
---|
Inlet/Outlet Size (in.) | 1/2 in. NPT x 1/2 in. NPT |
---|
Maximum Capacity (ft³/hr) | 200 ft³/hr |
---|
Maximum Capacity (m³/hr) | 5.7 m³/hr |
---|
Minimum Capacity (ft³/hr) | 20 ft³/hr |
---|
Minimum Capacity (m³/hr) | 0.6 m³/hr |
---|
Maximum Capacity at 1 in. P.D. (ft³/hr) | 150 ft³/hr |
---|
Maximum Capacity at 1 in. P.D. (m³/hr) | 4.2 m³/hr |
---|
Typical Ignition Hardware | Q3450; Q3480 |
---|
Product Family
All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.
UPS Hoilday Delivery Schedule
For more infomation about Returns visit Returns
For more informatrion about Warranty visit Warranty page.
You can also find answers to some common questions on our FAQ page
Reviews
Not reviewed yet, be the first to write one!
Add Review
|