• Ignition is on whenever the burner is on (intermittent ignition-also called constant ignition).
• Solid state flame sensing circuit.
• External button to manually reset safety switch after lockout.
• Enclosed safety switch must be manually reset after safety shutdown.
• R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment.
• Mounts on standard 4 x 4 in. junction box.
• C554A Cadmium Sulfide Flame Detector and a 24 Vac thermostat required.R8184M1051 Protectorelay Oil Burner Control, Intermittent Ignition, 45 sec. Safety SwitchIgnition Type | Intermittent |
---|
Timing, Safety Switch | 45 sec. |
---|
Overview | Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit. |
---|
Electrical Rating; Contacts (full load) | 7.4 A @ 120 Vac; 3.7 a @ 240 Vac |
---|
Electrical Rating; Contacts (locked rotor) | 44.4 A @ 120 Vac; 22.2 A @ 240 Vac |
---|
Mounting Bracket | Mounts on standard 4 x 4 in. junction box |
---|
Dimensions (in.) | 4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep |
---|
Dimensions (mm) | 111 mm high x 104 mm wide x 64 mm deep |
---|
Temperature Range (F) | -40 F to +130 F |
---|
Temperature Range (C) | -40 C to +54 C |
---|
Approvals, Underwriters Laboratories Inc | UL Component Recognized; File no. MP268, guide no. MCCZ2 |
---|